facilities:irradiation:bern_medical_cyclotron [23:25 24/05/2022] – [Facility] jhulsmanfacilities:irradiation:bern_medical_cyclotron [17:28 25/05/2022] (current) – [Facility] jhulsman
Line 4: Line 4:
   * [[https://www.lhep.unibe.ch/research/medical_applications/facility/index_eng.html|Facility Page]]   * [[https://www.lhep.unibe.ch/research/medical_applications/facility/index_eng.html|Facility Page]]
   * {{ :facilities:irradiation:bern_medical_cyclotron:sipm_workshop_-_cyclotron_for_rh.pdf |Presentation}}   * {{ :facilities:irradiation:bern_medical_cyclotron:sipm_workshop_-_cyclotron_for_rh.pdf |Presentation}}
 +  * [[https://arxiv.org/pdf/2201.04176.pdf|JINST Paper]]
  
 ===== Beam Parameters ===== ===== Beam Parameters =====
    
-^ Beam Source ^ Particle Type ^ Current ^ Energy ^ Notes ^  +^ Beam Source ^ Particle Type ^ Flux ($cm^{-2} s^{-1}$) ^ Energy ^ Notes ^  
-| IBA Cyclone 18/18 | proton | pA to $150 \mu A$ | 18MeV | 8 exit ports for targets/Beam Transfer Line |+| IBA Cyclone 18/18 | proton | $10^9$ to $10^{12}$ | 18MeV | 8 exit ports for targets/Beam Transfer Line 
 +| IBA Cyclone 18/18 | neutrons | ~$10^9$ | TBD | produced through converter targets at the end of the BTL|
  
 ===== Facility ===== ===== Facility =====
Line 20: Line 22:
 The protons are directed into a separate bunker (as depicted in the figure below) via a beam transfer line. It is 6.5m long and consists of 1 dipole doublet for horizontal/vertical steering and 2 quadrupole doublets for focusing. An additional neutron shutter (to stop the neutron flux) is included. 2 beam viewers provide a destructive beam current measurement. The protons are directed into a separate bunker (as depicted in the figure below) via a beam transfer line. It is 6.5m long and consists of 1 dipole doublet for horizontal/vertical steering and 2 quadrupole doublets for focusing. An additional neutron shutter (to stop the neutron flux) is included. 2 beam viewers provide a destructive beam current measurement.
  
-{{ :facilities:irradiation:bern_medical_cyclotron:bern_proton_btl.png?direct&600 | Beam Transfer Line schematic}} +{{ :facilities:irradiation:bern_medical_cyclotron:closedcyclotron.jpg?nolink&600|Beam Transfer Line photo}} 
-{{ :facilities:irradiation:bern_medical_cyclotron:closedcyclotron.jpg?direct&600 |Beam Transfer Line photo}}+{{:facilities:irradiation:bern_medical_cyclotron:bern_proton_btl.png?nolink&600|Beam Transfer Line schematic}}
  
-j+Collimators allow for proton beams to have an area of $1cm^2 \times 1 cm^2$ to $3cm^2 \times 3 cm^2$. Setups can be placed in front of the collimator on a motorized linear actuator. Setups can be irradiated in "passive mode". However, it is also possible to take data during the irradiation  via a patch panel (connected to the physics laboratory).